Current/Voltage Transducer Monitors

Results: 660
Stocking Options
Environmental Options
Media
Exclude
660Results

Showing
of 660
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
2813486
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
30
In Stock
174
Factory
1 : 305,48620 €
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
4 ~ 20mA
5000VAC (Test)
340ms
-
20 ~ 30VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
CE, cULus
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
37
In Stock
137
Factory
1 : 318,58000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
65
In Stock
1 : 328,72000 €
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
94
In Stock
1 : 328,73000 €
Box
Box
Active
Voltage Transducer
±1500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2906242
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
29
In Stock
242
Factory
1 : 396,37000 €
Bulk
Bulk
Active
Voltage Transducer
±660VDC
±10V
5300VAC (Test)
16ms
-
24VDC
DIN Rail
Screw Terminal
-25°C ~ 60°C
CE, cULus
E83-2050
TRANSDUCER CURRENT 10-40VDC
Carlo Gavazzi Inc.
10
In Stock
1 : 164,36000 €
Bag
Bag
Active
Current Transducer
0 ~ 50A
4 ~ 20mA
-
200ms
±2%
10 ~ 40VDC
DIN Rail
Screw Terminal
-20°C ~ 50°C
CE, UL
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
10
In Stock
1 : 174,26000 €
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 500VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
3
In Stock
1 : 174,26000 €
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 250VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
5
In Stock
1 : 215,82000 €
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
8
In Stock
1 : 306,39000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
0 ~ 10VDC
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
17
In Stock
4
Factory
1 : 318,58000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 200A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
18
In Stock
1 : 328,73000 €
Box
Box
Active
Voltage Transducer
±100V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
17
In Stock
1 : 328,73000 €
Box
Box
Active
Voltage Transducer
±300V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
16
In Stock
1 : 328,73000 €
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
8 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
17
In Stock
1 : 389,19000 €
Box
Box
Active
Voltage Transducer
±50V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
13
In Stock
1 : 389,19000 €
Box
Box
Active
Voltage Transducer
±750V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
15
In Stock
1 : 1 040,06000 €
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
20
In Stock
1 : 1 232,29000 €
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
15
In Stock
1 : 99,39000 €
Box
Box
Active
Average RMS AC Voltage Transducer
0 ~ 150VAC
4 ~ 20mA
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
DCSA50
TRANSDUCER CURRENT 10-30VDC
Littelfuse Inc.
4
In Stock
1 : 150,84000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 50mA
4 ~ 20mA, 1 ~ 10VDC
Not Isolated
300ms
±0.25%
10 ~ 30VDC
DIN Rail
Screw Terminal
-30°C ~ 60°C
CE, CSA, UL
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
13
In Stock
1 : 174,26000 €
Bulk
Bulk
Active
True RMS AC Voltage Transducer
0 ~ 150VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
2810612
TRANSDUCER CURRENT 24VDC
Phoenix Contact
11
In Stock
1 : 277,47000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
-
-
24VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
ATEX, cULus
2810625
TRANSDUCER CURR 19.2-253VAC/DC
Phoenix Contact
2
In Stock
1 : 321,86000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
200ms
-
19.2 ~ 253VAC/DC
DIN Rail
Screw Terminal
-20°C ~ 65°C
ATEX, cULus
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
6
In Stock
1 : 324,39000 €
Bulk
Bulk
Active
Current Transducer
0 ~ 300A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
IsoBlock I-FG-4C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
13
In Stock
1 : 953,84000 €
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
Showing
of 660

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.